The 8500B Series programmable DC electronic
loads improve upon all aspects of its predecessor
while maintaining dependability at a value price.
A set of comprehensive functions make these
loads a versatile tool for testing and evaluating
DC power supplies, DC-DC converters, batteries,
battery chargers, and photovoltaic arrays.
List mode, transient mode, automatic test mode,
and battery test mode offer a variety of test tools
for lab or production line applications.
Continuously switching and pulsing load
conditions put a dynamically changing load on
DC sources. Load behavior can be triggered
internally, externally, or remotely from the
included application software.
Contained in a compact benchtop form factor,
these loads operate in constant current (CC),
constant voltage (CV), constant resistance (CR),
or constant power (CW) mode. Internal memory
allows for 100 sets of user configurable
parameters such as voltage, current, slew rate and
width for quick system recall.
Special applications
Performance verification of photovoltaic
solar panels
CR-LED mode to simulate loading behavior
and test LED drivers
Fuel and solar cell tests
Battery test and power supply evaluations
Features and benefits (cont.)
n Adjustable slew rate in CC mode
n Flexible triggering options via front panel,
external input, timer, or bus
n Built-in battery test function, specify cut-off
voltage, capacity level, and time
n Test modes to validate the OCP/OPP protection
functions of a power supply
n OVP/OCP/OPP/OTP including local and remote
reverse voltage (LRV/RRV) protection
n Remote sense
n Short-circuit test
n Analog current control and monitoring
n Two thermostatically controlled fans
(linear-speed control to minimize noise)
n Integrated meter measures voltage, current, &
power
n Rack-mountable
Model 8542B 8500B 8502B 8510B 8514B
Power 150 W 300 W 300 W 600 W 1500 W
Rated Voltage 150 V 150 V 500 V 120 V 120 V
Rated Current 30 A 30 A 15 A 120 A 240 A
I/O Interface TTL (DB9) interface with USB adapter USB, RS232
Form Factor 2U half-rack 2U
Features and benefits
n Maximum input power 1500 W
n CC/CV/CR/CW operating modes
n 16-bit voltage and current measurement system
providing up to 0.1 mV / 0.1 mA resolution
n Transient mode up to 10 kHz in CC mode
n List mode function for custom step sequences
n Supports both SCPI and backwards compatible
8500 series protocol
n Store and recall up to 100 instrument settings
USB RS232