User Manual
42
Similarly, after setting the master set ‘Phase Ctrl’ of the remaining two AC sources to
‘Slave’. The slaves will automatically connect to the master.
This completes the set-up process for three phase operation.
3) 3-Phase parameters and output
3-Phase parameters include: Voltage (rms), Frequency (Hz), and Phase (deg). The
reference phase of the master is always fixed at 0 degrees. The phase angle of slave
sources can be adjusted from 0 to 359.7 degrees.
The coupling mode can be changed to AC+DC in 3-phase mode to add a positive or
negative DC offset to the AC signal. The DC offset can be set from -424 V to +424 V.
Output of the system is controlled by the master. Enabling/disabling the output of the
master also enables/disables the output of slave instruments.
11.2 3-Phase Ddapter Digital I/O Pin Definitions
TL983P
Pin
9830B Digital
I/O pin
Function
1
23
RX
2
11
TX
3
10
GND
4
19
Remote inhibit
5
4
AC ON
6
16
Fault out
7
Reserved
-
8
Reserved
-
Table 11.2: TL983P pin definitions
The 8-pin digital I/O terminal block on the rear of the
TL983P adapter preserves commonly used signals. See
Table 11.2 for the pin definitions. To insert a wire into
the digital I/O block: press the orange tab in, insert
wire, and release the tab to hold the wire in place.
Digital I/O pinout