User Manual

34
9.3 System Error
The System Clear Error page is used to view and clear the error log. Use key or
rotary knob to see other error messages.
Figure 32 System Error Log
To clear the error log Press the arrow key ( ) to move the cursor to Clear Error?
(Yes/No) then press the ENTER key to change its value. Select YES, then press ENTER key
again to clear error log. The log errors cannot be recovered once it has been cleared.
Error Code
Definition
0x00000080
FW_VerError
0x00000040
SW_EShoutdown
0x00000020
SW_OVAP Software
0x00000010
SW_OPP Software
0x00000008
SW_OVP
0x00000004
SW_OCP
0x00000002
SW_CAN2Error
0x00000001
SW_CAN1Error
0x00018000
AC Input Fail
0x00040000
HW Over Voltage
0x88E00000
HW Over Current
0x33180000
Over Temperature
0x00004000
FAULT_FAN_FAIL
0x00002000
FAULT_CURR_LIMIT
0x00001000
FAULT_CURR_OVSPEC
0x00000800
AC Input too low
0x00000400
AC Input too high
0x00000200
PFC Vbus too high
0x00000100
AC Input Freq. Error