Press the arrow key ( ) to move the cursor to the wanted configuration. Press the
ENTER key to change its value then press the ENTER again key to confirm.
See the example below:
Move the cursor to Waveform Select, then press OK or Enter. Press the A softkey then
press OK or Enter to confirm. Use keys (or Rotary knob) to select the other
configurations.
Figure 28 - Configuration 2 page
8.3 Limits
The Configuration Limits page is used to set user-defined voltage, current and power
limits.
Configurations
Range
Description
Volts (rms)
0.0 to 306.0 Vrms
Set the limit value of AC output voltage
Volts (Vp) +
0.0 to 427.0 V
Set the limit value of positive DC output
voltage
Volts (Vp) -
-427.0 to 0.0 V
Set the limit value of negative DC output
voltage
A
0.00 to 33.00 A
Set the limit value of AC output current
A Delay (ms)
0 to 10000 ms
Set the time delay to activate protection
when the current limit is reached
Power
0 to 3300.00 VA
Set the limit value of output power
Table 12 - Limits descriptions