User Manual
27
8 Configure Menu
In Setting and Measure page, press Configure key to open the Configuration page. The
Configuration page includes three softkey options:
1. Config 1 (default)
2. Config 2
3. Limits
Each of these pages will be explained below with more detail.
Figure 26 - Default Configuration 1 Menu
8.1 Config 1
Configurations listed below can be edited in this Configuration 1 page.
Configurations
Range
Description
Range
150 V, 300 V
Select the range of AC output voltage
Couple
AC, DC or
AC+DC
Select the coupling of output voltage
Power On State
OFF, LAST, USER
OFF: When power on, the output is OFF.
LAST: When power on, the settings will
restore to the pre-shutdown state.
USER: When power on, users need to set the
output value and status. (Volts(rms),
Volts(DC), Freq, Sync Source )
Inrush Current
Measurement
Time (ms)
0 to 10000 ms
Set the time interval to measure Inrush
current
Inrush Current
Delay Time (ms)
0 to 10000 ms
Set the delay time to measure Inrush current
Table 11 - Config 1 Configurations