User Manual

171
<10mV/<0.1mA (9184B)
<20mV/<0.01mA (9185B)
Programming and Readback Accuracy ±(% output+offset)
Voltage
0.05%+5mV(9171B,9173B,9181B,
9182B)
0.05%+10mV(9172B,9174B,9183B)
0.05%+50 mV(9184B)
0.05%+100mV(9185B)
Current
0.1%+2mA (9171B,9173B,9181B,9183B)
0.1%+1mA (9172B,9174B,9184B)
0.1%+5 mA (9182B)
0.1%+0.1 mA (9185B)
Temperature Coefficient per °C ±(% output+offset)
Voltage
0.005%+1mV
0.005%+10 mV (9184B)
0.005 %+20 mV (9185B)
Current
0.01%+3mA
Stability (8 hrs) ±(% output+offset)
Voltage
0.02%+2mV
0.02 %+10 mV(9184B)
0.02%+20 mV(9185B)
Current
0.1%+1mA
Settling Time
2
30ms
Measurement Time
5ms
Transient Response Time
3
50μs (9171B - 9183B)
100μs (9184B, 9185B)
OVP Accuracy
0.5%+0.1V (9171B 9183B)
0.5%+1V (9184B, 9185B)
OCP Accuracy
0.5%+0.1A
OVP/OCP Activation Time
4
1mS