User Manual

155
supply. This command functions the same as *IDN?,
however this is used in a multi unit programming
setup for the selected power supply.
Query:
CIDN?
Return String:
B&K PRECISION,9171B,SN#,1.10,0
CREV?
Description:
Queries the firmware version of the selected power
supply.
Query:
CREV?
Return String:
1.10
CSN?
Description:
Queries the serial number of the selected power
supply.
Query:
CSN?
Return String:
123D19238
Serial number is 123D19238.
CST?
Description:
Queries the status of the selected power supply. This
command functions the same as STATUS?
command, however this is used in a multi unit
programming setup for the selected power supply.
Query:
CST?
CCLR
Description:
Clears the protection flag/trip of the selected power
supply.
Syntax:
CCLR
Output Control Command
This set of commands controls the outputs of the selected
instrument (based on their address). Use CADR
command(described in previous section) first to select the address
of the unit you want to control before using any of these commands