commands in order:
PROG 1
Choose program number
PROG:CLE
Clear program 1 data
PROG:REP 0
No repeat (repeat one time for “1”)
PROG:TOTA 8
Set program 1 to have 8 steps in total
PROG:STEP 1
Following 3 settings are for step 1
PROG:STEP:CURR 1
Set output current to 1 ampere
PROG:STEP:VOLT 5
Output voltage is set to 5 volts
PROG:STEP:ONT 0.1
Output ON time is set to 0.1 sec
PROG:STEP 2
Following 3 settings are for step 2
PROG:STEP:CURR 1
PROG:STEP:VOLT 10
PROG:STEP:ONT 0.1
PROG:STEP 3
Choose step 3
PROG:STEP:CURR 1
PROG:STEP:VOLT 15
PROG:STEP:ONT 0.1
PROG:STEP 4
Choose step 4
PROG:STEP:CURR 1
PROG:STEP:VOLT 20
PROG:STEP:ONT 0.1
PROG:STEP 5
Choose step 5
PROG:STEP:CURR 1
PROG:STEP:VOLT 15
PROG:STEP:ONT 0.1
PROG:STEP 6
Choose step 6
PROG:STEP:CURR 1
PROG:STEP:VOLT 10
PROG:STEP:VOLT 10
PROG:STEP:ONT 0.1
PROG:STEP 7
Choose step 7
PROG:STEP:CURR 1
PROG:STEP:VOLT 5
PROG:STEP:ONT 0.1
PROG:STEP 8
Choose step 8