Description:
Configures/Queries the ISET current setting for
channel 2.
Syntax:
[SOURce]:CURR2<SP><current>
[SOURce]:CURR2?
<current> - 0 – max. rated current.
Example:
SOUR:CURR21.456
Set current of channel 2 to 1.456 A.
Query:
SOUR:CURR2?
Return String:
1.456
Format:
<NRf>
[SOURce]:CURR2:PROTection
Note:
See PROTection:OCP2 command.
[SOURce]:CURR2:PROTection:LEVel
Note:
See PROTection:OCP2:LEVel command.
[SOURce]:VOLTage
Description:
Configures/Queries the VSET voltage setting. For
dual channel models, use [SOURce]:VOLT2
command for channel 2.
Syntax:
[SOURce]:VOLTage<SP><voltage>
[SOURce]:VOLTage?
<voltage> - 0 – max. rated voltage.
Example:
SOUR:VOLT20.000
Set voltage to 20.000 V.
Query:
SOUR:VOLT?
Return String:
20.000
Format:
<NRf>
[SOURce]:VOLTage:PROTection
Note:
See PROTection:OVP command.
[SOURce]:VOLTage:PROTection:LEVel
Note:
See PROTection:OVP:LEVel command.