User Manual
124
Query:
PROG:STEP?
Return String:
30
Currently selecting step 30 in the sequence for setup.
Format:
<number>
PROGram:STEP:CURRent
Description:
Configures/Queries the current setting for the
selected step (use PROGram:STEP command to
select step). For dual channel models, this will be for
channel 1.
Syntax:
PROGram:STEP:CURRent<SP><current>
PROGram:STEP:CURRent?
<current> - 0 – max. rated current.
Example:
PROG:STEP:CURR 1.234
Set 1.234 A as current setting for the selected step in
the program sequence.
Query:
PROG:STEP:CURR?
Return String:
1.234
Format:
<NRf>
PROGram:STEP:CURR2
Note:
For dual channel models only.
Description:
Configures/Queries the current setting for the
selected step (use PROGram:STEP command to
select step) for channel 2.
Syntax:
PROGram:STEP:CURR2<SP><current>
PROGram:STEP:CURR2?
<current> - 0 – max. rated current.
Example:
PROG:STEP:CURR2 1.234
Set 1.234 A as current setting for the selected step in
the program sequence for channel 2.
Query:
PROG:STEP:CURR2?
Return String:
1.234
Format:
<NRf>