User Manual
120
OUTput:SR:CURRent
Description:
Configures/Queries the current slew rate in unit of
A/ms. For dual channel models, this will configure the
slew rate for channel 1.
Syntax:
OUTput:SR:CURRent<SP><current>
OUTput:SR:CURRent?
<current> - Current value. 0 – max. current slew rate
value. See “Slew Rate Configuration” in section 3.5.
Example:
OUT:SR:CURR 1.000
Sets the current slew rate to 1.000 A/ms.
Query:
OUT:SR:CURR?
Return String:
1.000
Format:
<NRf>
OUTput:SR:CURR2
Note:
For dual channel models only.
Description:
Configures/Queries the current slew rate for channel
2.
Syntax:
OUTput:SR:CURR2<SP><current>
OUTput:SR:CURR2?
<current> - Current value. 0 – max. current slew rate
value. See “Slew Rate Configuration” in section 3.5.
Example:
OUT:SR:CURR2 1.000
Sets the current slew rate to 1.000 A/ms.
Query:
OUT:SR:CURR2?
Return String:
1.000
Format:
<NRf>
OUTput:STATe?
Description:
Queries the output mode. For dual channel models,
this will query for channel 1.
Syntax:
OUTput:STATe?
Query:
OUT:STAT?
Return String:
CV
Format:
CV or CC