User Manual
84 
1.  Press          , then    to enter SYSTEM SETTING. Select 
POWER ON STATE. Press   or   to change it to LAST 
for setting the power on state to last known configuration. 
Select OFF to turn it off. 
2.  Press        to confirm the change. 
3.11 Sequence Program Mode 
Up to 10 (1 – 10) programmed sequences can be stored into the 
internal memory of the power supply and be executed from the front 
panel or via remote commands. A sequence consists of various 
steps of voltage and current values with a user defined time to hold 
at each step. This allows the user to change the voltage and current 
output of the power supply at different timings in a sequence. The 
maximum number of steps per sequence is 150, and the 
minimum timing in between steps is 10 ms. For dual channel 
models, the programmed sequence will control both channels 
per every step. Programming a sequence for each channel 
independently is not supported. 
Sequences must be programmed into the memory via remote 
interface (i.e. USB, GPIB, Ethernet) before it can be executed from 
the front panel. See “4 Remote Operation” for details. 
Assuming that sequences are already programmed into the internal 
memory, follow these steps to execute a program. 
Menu 
1 
Enter 