User Manual

158
Format:
<voltage>,<current>
COUT/COUT2
Description:
Configures/Queries the output state of the selected
power supply. See OUT/OUT2 command for similar
syntax.COUT2 is for dual channel models only.
Example:
COUT ON
Sets the selected power supply’s output to ON.
COUT2?
Queries the selected power supply’s second channel
output state.
COUTA
Note:
For dual channel models only.
Description:
Configures the output state of both channels of the
selected power supply.
Example:
COUTA ON
Enables both channel outputs of the selected dual
channel power supply.
COV/COV2
Description:
Configures/Queries the over voltage protection value
of the selected power supply. See OVSET/OVSET2
command for similar syntax. COV2 is for dual
channel models only.
Example:
COV 70.000
Sets the selected power supply’s OVP value to
70.000V.
COV2?
Queries the selected power supply’s second channel
OVP value.
COVP/COVP2
Description:
Configures/Queries the over voltage protection state
of the selected power supply. See OVP/OVP2
command for similar syntax. COVP2 is for dual
channel models only.
Example:
COVP ON
Sets the selected power supply’s OVP state to ON.
COVP2?
Queries the selected power supply’s second channel