User Manual
124 
Query: 
PROG:STEP? 
Return String: 
30 
Currently selecting step 30 in the sequence for setup. 
Format: 
<number> 
PROGram:STEP:CURRent 
Description:  
Configures/Queries the current setting for the 
selected step (use PROGram:STEP command to 
select step). For dual channel models, this will be for 
channel 1. 
Syntax: 
PROGram:STEP:CURRent<SP><current> 
PROGram:STEP:CURRent? 
<current> - 0 – max. rated current. 
Example: 
PROG:STEP:CURR 1.234 
Set 1.234 A as current setting for the selected step in 
the program sequence. 
Query: 
PROG:STEP:CURR? 
Return String: 
1.234 
Format: 
<NRf> 
PROGram:STEP:CURR2 
Note: 
For dual channel models only. 
Description:  
Configures/Queries the current setting for the 
selected step (use PROGram:STEP command to 
select step) for channel 2. 
Syntax: 
PROGram:STEP:CURR2<SP><current> 
PROGram:STEP:CURR2? 
<current> - 0 – max. rated current. 
Example: 
PROG:STEP:CURR2 1.234 
Set 1.234 A as current setting for the selected step in 
the program sequence for channel 2. 
Query: 
PROG:STEP:CURR2? 
Return String: 
1.234 
Format: 
<NRf> 