User Manual
158 
Format: 
<voltage>,<current> 
COUT/COUT2 
Description:  
Configures/Queries the output state of the selected 
power supply. See OUT/OUT2 command for similar 
syntax.COUT2 is for dual channel models only. 
Example: 
COUT ON 
Sets the selected power supply’s output to ON. 
COUT2? 
Queries the selected power supply’s second channel 
output state. 
COUTA 
Note: 
For dual channel models only. 
Description:  
Configures the output state of both channels of the 
selected power supply. 
Example: 
COUTA ON 
Enables both channel outputs of the selected dual 
channel power supply. 
COV/COV2 
Description:  
Configures/Queries the over voltage protection value 
of the selected power supply. See OVSET/OVSET2 
command for similar syntax. COV2 is for dual 
channel models only. 
Example: 
COV 70.000 
Sets the selected power supply’s OVP value to 
70.000V.  
COV2? 
Queries the selected power supply’s second channel 
OVP value. 
COVP/COVP2 
Description:  
Configures/Queries the over voltage protection state 
of the selected power supply. See OVP/OVP2 
command for similar syntax. COVP2 is for dual 
channel models only. 
Example: 
COVP ON 
Sets the selected power supply’s OVP state to ON. 
COVP2? 
Queries the selected power supply’s second channel 