User Manual

39
3. Press the key to select Slave or Master. Use the keys to select between the
two options. Select Master to set the power supply as a master, or select Slave to set
the power supply as a slave. Always set the Slave supplies first and Master supply last.
4. Press the key to select Addr…. Press and the display will prompt to enter an
address. Use the numeric keypad to enter an Address, which must be different than all
other power supplies that you want to connect together in parallel. Enter any number
between 0 31.
5. Press to save the changes.
6. Exit the menu by pressing several times.
3.5 Program Sequence Mode (List mode)
Note: Internal List mode functionality is not available on model 9117
List mode functionality is only available in the software program for model 9117.
The power supply (models 9115(-AT) and 9116 only) has a list mode feature that allows storing
programmed sequences into internal non-volatile memory and recalling and running them per
configured parameters. A total of 10 steps can be configured for each sequence, and a total of
10 sequences are available for storage. Additionally, multiple sequences or all 10 sequences can
be saved into a program configuration, where each program configuration allows running one
sequence after another. This allows for a total maximum of 100 steps in one program
configuration. Up to 10 program configurations can be saved and recalled to and from the non-
volatile memory. Below is an illustration of how programmed sequences are structured, stored,
and recalled.