User Manual
23 
Power-On 
Rst 
Load Setup 
Off 
External Control 
10v-M 
Limit 
Vmin = 0.000V, Vmax = 81.000V 
Online Setup 
Off 
Output 
Disabled 
Configure Power-On State 
The initial power-On state of the power supply can be configured by following the steps below: 
1.  From the SYSTEM menu, select Power-On and press . 
2.  There are two options: 
Rst(Def) – Factory Default. 
Sav0 – Settings before last power up. 
3.  Select the settings you want during power up, and press   to save changes. 
4.  To exit the menu at any time, press   twice. 
Configure Trigger Source 
The trigger function is used to initiate the start of running a program sequence (list). The trigger 
source can be set so that users can send a trigger from the front panel or through a remote 
command via remote interface. Follow the below steps to configure the trigger mode: 
1.  From the SYSTEM menu, browse and select Trigger and press . 
2.  There are two options: 
Manual(Def) – Manual trigger. Front panel trigger button is used to send a trigger 
(press  and  to send trigger). 
Bus – Bus trigger. Remote command *TRG is used to send a trigger. 
3.  To exit the menu at any time, press   twice. 