User Manual
82 
Models 
8600 
8601 
8602 
Transient Mode (CC mode) 
T1 & T2 
1
20 µs – 3600 s / Resolution: 10 µs 
 Accuracy 
5 µs + 100 ppm 
Slew 
Rate 
2 
Low Rate 
0.001-2.5 A/ms 
0.001-1 A/ms 
High Rate 
0.001-2.5 A/µs 
0.001-1 A/µs 
 Accuracy 
within 40 % of programmed value 
Measurement 
Readback Voltage 
Range 
Low 
0 – 18 V 
0 – 18 V 
0 – 50 V 
High 
0 – 120 V 
0 – 120 V 
0 – 500 V 
Resolution 
Low 
1 mV 
High 
10 mV 
Accuracy 
±(0.05 %+0.05 % FS) 
Readback Current 
Range 
Low 
0 – 3 A 
0 – 6 A 
0 – 3 A 
High 
0 – 30 A 
0 – 60 A 
0 – 15 A 
Resolution 
Low 
0.01 mA 
0.1 mA 
0.01 mA 
High 
0.1 mA 
1 mA 
0.1 mA 
Accuracy 
±(0.05 %+0.05 % FS) 
±(0.05 %+0.1 % FS) 
±(0.05%+0.05 % FS) 
Readback Power 
Range 
150 W 
250 W 
200 W 
Resolution 
10 mW 
Accuracy 
±(1 %+0.1 % FS) 
±(0.2 %+0.2 % FS) 
±(0.1 %+0.1 % FS) 
Protection Range (typical) 
OPP 
150 W 
250 W 
200 W 
OCP 
Low 
3.3 A 
6.6 A 
3.3 A 
High 
33 A 
66 A 
16.5 A 
OVP 
120 V 
120 V 
500 V 
OTP 
85℃ 
General (typical) 
Short Circuit 
Current 
(CC) 
Low 
3.3 A 
6.6 A 
3.3 A 
High 
33 A 
66 A 
16.5 A 
Voltage 
0 V 
Resistance 
35 mΩ 
30 mΩ 
300 mΩ 
Input Terminal 
Impedance 
150 kΩ 
300 kΩ 