User Manual
69 
PRG01 from this display indicates which program has been loaded to run. Depending on 
which program is recalled, it will show PRG01-PRG10. 
  STOP indicates the program is not running. 
4.  Now, press  ( ) once to start running the program. The display will change to: 
 -01 next to PRG01 indicates the current running sequence number within the selected 
program number. 
on indicates the input state is enabled for the selected sequence. If On Time is not set 
to 0.0S for the sequence, it will show on. This indicator can also show off to indicate the 
input state is disabled. If short is selected for the sequence, it will display short. 
pass indicates at the current sequence has passed the test. If a failure occurs, it will 
indicate fail. 
5.  If pause is activated for a selected sequence while running the program, the display will 
show: 
10.000V 
0.000A 
PRG01 -01  on        pass 
OFF CC 
10.000V 
0.000A 
PRG01  STOP 
OFF CC 