This parameter refers to the current high limit for the automatic test mode. During automatic 
test mode, the device under test (DUT) must be operating below the configured value for the 
test to PASS upon completion. If the DUT operates above the configured value, the test will FAIL 
upon completion. 
Note: This parameter is used for Automatic Test Function ONLY. 
Low 
This parameter refers to the current low limit for the automatic test mode. During automatic 
test mode, the DUT must be operating above the configured value for the test to PASS upon 
completion. If the DUT operates below the configured value, the test will FAIL upon completion. 
Note: This parameter is used for Automatic Test Function ONLY. 
Constant Resistance (CR) Mode 
In this mode, the electronic load is equivalent to a constant resistance, as shown below. The 
electronic load will linearly change the current, according to the input voltage. 
Configure CR Parameters 
There are several parameters that should be set up prior to operating in CR mode.  Press 
 so that it lights up, then press   ( )and   to access Setup for CR mode. 
The setup menu will be shown: 