User Manual
82
Models
8600
8601
8602
Transient Mode (CC mode)
T1 & T2
1
20 µs – 3600 s / Resolution: 10 µs
Accuracy
5 µs + 100 ppm
Slew
Rate
2
Low Rate
0.001-2.5 A/ms
0.001-1 A/ms
High Rate
0.001-2.5 A/µs
0.001-1 A/µs
Accuracy
within 40 % of programmed value
Measurement
Readback Voltage
Range
Low
0 – 18 V
0 – 18 V
0 – 50 V
High
0 – 120 V
0 – 120 V
0 – 500 V
Resolution
Low
1 mV
High
10 mV
Accuracy
±(0.05 %+0.05 % FS)
Readback Current
Range
Low
0 – 3 A
0 – 6 A
0 – 3 A
High
0 – 30 A
0 – 60 A
0 – 15 A
Resolution
Low
0.01 mA
0.1 mA
0.01 mA
High
0.1 mA
1 mA
0.1 mA
Accuracy
±(0.05 %+0.05 % FS)
±(0.05 %+0.1 % FS)
±(0.05%+0.05 % FS)
Readback Power
Range
150 W
250 W
200 W
Resolution
10 mW
Accuracy
±(1 %+0.1 % FS)
±(0.2 %+0.2 % FS)
±(0.1 %+0.1 % FS)
Protection Range (typical)
OPP
150 W
250 W
200 W
OCP
Low
3.3 A
6.6 A
3.3 A
High
33 A
66 A
16.5 A
OVP
120 V
120 V
500 V
OTP
85℃
General (typical)
Short Circuit
Current
(CC)
Low
3.3 A
6.6 A
3.3 A
High
33 A
66 A
16.5 A
Voltage
0 V
Resistance
35 mΩ
30 mΩ
300 mΩ
Input Terminal
Impedance
150 kΩ
300 kΩ
1 MΩ