User Manual
84 
Models 
8610 
8612 
8614 
8616 
Transient Mode (CC mode) 
T1 & T2
1
20 µs – 3600 s/Resolution: 10 µs 
Accuracy 
5 µs + 100 ppm 
Slew Rate
2 
Low 
Rate 
0.001-0.25 A/µs 
0.0001-0.1 A/µs 
0.001-0.25 A/µs 
0.0001-0.1 A/µs 
High 
Rate 
0.01-2.5 A/µs 
0.001-1 A/µs 
0.01-2.5 A/µs 
0.001-1 A/µs 
Accuracy 
within 40% of programmed value 
Measurement   
Readback Voltage 
Range 
Low 
0 – 18 V 
0 – 50 V 
0 – 18 V 
0 – 50 V 
High 
0 – 120 V 
0 – 500 V 
0 – 120 V 
0 – 500 V 
Resolution 
Low 
0.1 mV 
1 mV 
0.1 mV 
1 mV 
High 
1 mV 
10 mV 
1 mV 
10 mV 
Accuracy 
±(0.05%+0.05%FS) 
Readback Current 
Range 
Low 
0 – 12 A 
0 – 3 A 
0 – 24 A 
0 – 6 A 
High 
0 – 120 A 
0 – 30 A 
0 – 240 A 
0 – 60 A 
Resolution 
Low 
1 mA 
0.1 mA 
1 mA 
0.1 mA 
High 
10 mA 
1 mA 
10 mA 
1 mA 
Accuracy 
±(0.05%+0.1%FS) 
±(0.05%+0.05%FS) 
±(0.05%+0.1%FS) 
±(0.05%+0.05%FS) 
Readback Power 
Range 
750 W 
1500 W 
1200 W 
Resolution 
10 mW 
100 mW 
Accuracy 
±(0.2%+0.2%FS) 
Protection Range (typical) 
OPP 
760 W 
1550 W 
1250 W 
OCP 
Low 
13.2 A 
3.3 A 
26.4 A 
6.6 A 
High 
132 A 
33 A 
264 A 
66 A 
OVP 
130 V 
530 V 
130 V 
530 V 
OTP 
85℃ 
General (typical) 
Short Circuit 
Current 
(CC) 
Low 
13.2 A 
3.3 A 
26.4 A 
6.6 A 
High 
132 A 
33 A 
264 A 
66 A 
Voltage 
0 V 
Resistance 
10 mΩ 
120 mΩ 
6 mΩ 
60 mΩ 
Input Terminal 
Impedance 
300 kΩ 
1 MΩ 
300 kΩ 
1 MΩ 
Notes: 
1)  Fast pulse trains with large transitions may not be achievable. 