User Manual
26 
Configure CW Parameters 
There are several parameters that should be set up prior to operating in CW mode. Press 
 so that it lights up, then press   ( )and   to access Setup for CW 
mode. The setup menu will be shown: 
The setup parameters are: Range, High (Voltage limit), and Low (Voltage limit). Use the 
( or  ) keys to select each parameter, and use the numeric keypad to change the 
value. Press  to confirm the change. 
Range 
Use the numeric keypad to change the range. This value will also act as a limit to how much 
power the load can be configured to. The adjustable ranges vary depending on the model. See 
specifications for details. 
High 
This parameter refers to the voltage high limit for the automatic test mode. During automatic 
test mode, the device under test (DUT) must be operating below the configured value for the 
Constant Power 
Range=250.00W 