User Manual
Step 7 – Select upper limit of input
current
This parameter is used to limit testing
or test setups that must stay within a
customized range of values. Change
this value to the upper bound limit for
the input current. If current exceeds
this limit while the sequence is
running this step, it will stop and
show an error condition. See “Error
Condition” section for details. In this
example, we will set to 30.00 A.
Press to go and configure
the next parameter.
View
C
Recall
CC
Short CV
OFF
Shift
30A
CR
A
B
C
D
Set
V
W
A
150W DC Electronic Load
8540
Programmable Range: 0.00 – 30.00
Use the keys to change cursor
position shown by the LED light next to
either A, B, C, or D (These four denotes
cursor position, with A selecting the most
significant figure and D the least significant
figure.
BB
AA
Step 8 – Select lower limit of input
current
This parameter is used to limit testing
or test setups that must stay within a
customized range of values. Change
this value to the lower bound limit for
the input current. If current is less
than this limit while the sequence is
running this step, it will stop and
show an error condition. See “Error
Condition” section for details. In this
example, we will set to 0.00 A.
Press to go and configure
the next parameter.
View
C
Recall
CC
Short CV
OFF
Shift
30A
CR
A
B
C
D
Set
V
W
A
150W DC Electronic Load
8540
Programmable Range: 0.00 – 30.00
Use the keys to change cursor
position shown by the LED light next to
either A, B, C, or D (These four denotes
cursor position, with A selecting the most
significant figure and D the least significant
figure.
BB
AA