User Manual
Step 3 – Select step value
Select the data value you want
programmed for the selected step. If
you enter 0.000, this denotes the end
of the sequence and it will stop on
this step. The maximum value will
depend on the type selected in
previous step. See programmable
range on the right for reference. In
this example, we will enter 1.000 A.
Press to go and configure
the next parameter.
View
C
Recall
CC
Short CV
OFF
Shift
30A
CR
A
B
C
D
Set
V
W
A
150W DC Electronic Load
8540
Step 4 – Select delay time
“dt” on the top display refers to delay
time for the selected step. In this
example, we will set it to 5 seconds.
Press to go and configure
the next parameter.
Recall
CC
Short CV
OFF
Shift
30A
CR
A
B
C
D
Set
V
W
A
150W DC Electronic Load
8540
Programmable Range: 0.000 (CC) / 0.100
(CV) / 0.100 (CR) – 30.00 (CC) / 60.0 (CV)
/ 4000 (CR)
Use the keys to change cursor
position shown by the LED light next to
either A, B, C, or D (These four denotes
cursor position, with A selecting the most
significant figure and D the least significant
figure.
BB
AA
Programmable Range: 0.4 seconds to 25
seconds.
Use the keys to change cursor
position shown by the LED light next to
either A, B, C, or D (These four denotes
cursor position, with A selecting the most
significant figure and D the least significant
figure.
View
C
BB
AA