Ton, To and Tpf (P/F) Relation:
Tpf the delay time for a step
15. Set stop conditions: COMP means stop test when all the steps are completed, FAILURE means stop test when the
testing fails. Press to conrm.
STOP COMP FAILURE
16. Select the test le to link if you’d like to. The linked le must be saved before. 0 stands for not linking to other les.
Press key to conrm.
CHAIN PROGRAM =0(0-10)
Program/Save Locations
PROGRAM Sequence 1 1 2 3 4 5 6 7 8 9 10
Save Group 1 2 3 4 5 6 7 8 9 10
PROGRAM Sequence 2 1 2 3 4 5 6 7 8 9 10
Save Group 11 12 13 14 15 16 17 18 19 20
PROGRAM Sequence 10 1 2 3 4 5 6 7 8 9 10
Save Group 91 92 93 94 95 96 97 98 99 100
17. Save the edited les in EEPROM, you can save up to 10 groups of les, e.g please press to save the edited le
in group 1, and then press to conrm.
SAVE PROGRAM =1(1-10)
18. Select a operation mode and then press +[CV] to set related parameters
10.0000V 0.0000A
0.00W CC=1.000A
19. Edit the three steps of the test le, details refer to below procedure. After all the steps are set , Press to exit
setup, and then press + to save.
You need to recall the test le before running it
Set the steps of a test le in the example
CC Mode, 1.2A, Voltage Range 4.4V-4.6V