User Manual

Battery Capacity Analyzer User Manual
38
7 Specications
Range
Open voltage 5.5 V to 30 V
6 Volts
Battery test 5.5 V to 6.8 V
Charge circuit test 5.5 V to 8.5 V
12 Volts
Battery test 8 V to 14 V
Charge circuit test 8 V to 17 V
24 Volts
Battery test N/A
Charge circuit test 16 V to 28 V
Current 1 A to 10 A
Resistance (IR) 1 mΩ to 100 mΩ
Setting
Voltage (record mode) 6 V, 12 V
Ah (record mode) 1 Ah – 100 Ah in 1 A steps
Current (load test mode) 0.5 A to 10 A in 0.5 A steps
Time (load test mode) 0.5 sec to 5 sec in 0.5 sec steps
Nominal Internal Resistance
(NIR)
N/A, 0.1 mΩ to 199 mΩ
Temperature (record mode) User settable
Real Time Clock
Data Time Log
Cycle Time 5 seconds, typical
Battery Load current 0.1 C based on Ah value entered by user
SOC tables
2 default tables, one for 6 and one for 12 V
3 user configurable tables for 6 V
3 user configurable tables for 12 V
Battery Charger Circuit Test
6, 12 or 24 Volt Charger
Circuits
Quick Test mode
Measurement data is
displayed but not recorded
Record mode
Records open and loaded
charger circuit voltage
Pass / Fail Optional, calculated based on user provided NIR
General
Internal Memory 50 records
Minimum Operating Voltage 5.5 V
Minimum Operating Current 0.45 A with back light on, typical
Display 20 x 4 LCD with back light
Remote Communication USB Cable (type B)
Test Leads Type Detachable
Storage Temperature -10º C to 70º C
Dimensions (W x H x D) 2.91” x 10.44” x 2.28” (74 x 265.1 x 58 mm)
Weight 2.65 lbs (1.2 kg)
Warranty One year
Included Accessories
USB (type B) cable, two sets alligator test leads,
adapter for testing charger circuit, test report,
certificate, user manual available for download.
603B
Displayed
Quick Test Mode
VO Voltage open
VL Voltage loaded
IR Internal resistance
SOC State of charge percentage
RS Resistance status, pass/fail user configured
Record Mode
VO Voltage open
VL Voltage loaded
IR Internal resistance
SOC State of charge percentage
SOT SOC table used for test
Tmp User provided temperature
RS Resistance status, pass/fail user configured
Recorded
Data
Rec Record number
Dat Date
Tme Time
Bld Building
Loc Location
Typ Type of system
Ser Battery serial number
Mfd Battery manufacturer or in-service date
Tmp User provided temperature
V Battery voltage (as labeled)
Ah Battery ampere hour (as labeled)
VO Voltage open
VL Voltage loaded
RC Remaining capacity (SOC)
NIR Nominal internal resistance used for test
IR Measured internal resistance
OCV Open charger voltage
LCV Loaded charge voltage
WEI Weighting state during test, Y or N
SOT SOC table used for test
SOV SOC voltage used for test
Accuracy
Voltage 0.2% ±10 mV
Current 0.2% ±10 mA
Resistance (IR) 5% ±1 mΩ