User Manual
10
Section 2 Operation
FRONT PANEL CONTROLS
Refer to the Front view of the unit.
1) Ah Range : With this key the user can select the
correct Ah range according to the battery
under test.
2) Ah Select LED: This LED in ON to indicate that the user can
select the Ah range.
3) Ah Setting Saved LED: This LED is ON when the unit locks to a
particular Ah range set by the user.
4) Display Mode: This key selects the display either as
No load voltage or % balance
capacity.
5) Battery Voltage: Indicates that the Battery voltage is being
displayed.
6) Battery Capacity %: This LED is ON when remaining capacity
is being displayed.
7) Load Test: The test starts by pressing this key.
8) Ready/Complete: When this LED is ON and steady, indicates
that the unit is ready to conduct a test.
9) Test In Progress: This LED is ON for approx. 3 sec. when
the battery test is carried out.
10) Reverse Polarity: If the unit is connected to a battery in
reverse polarity this LED will be ON.
11) LED Display Displays either battery voltage or battery
capacity percent.
12) +ve Cable Positive connecting cable with strain relief.