Burst Function 53
Function Explanation
Delay Set the delay time before the burst starts.
Trig Out O Disable trigger out.
On Enable trigger out.
Page 2/2 Return to the previous page.
Figure 11.2 N-Cycle Burst Interface (Page 2/2)
11.1.2 Innite
In innite mode, the cycle number of the waveform is set as an innite value.
The generator outputs a continuous waveform after receiving the trigger signal. Waveforms that support innite mode
include sine, square, ramp, pulse and arbitrary.
Press Burst → NCycle → Innite, and set the trigger source to “external” or
“manual”. The screen will display an innite cycle burst, as shown in Figure 11.3.
Figure 11.3 Innite Burst Interface
11.1.3 Gated
In gated mode, the generator controls the waveform output according to the gate signal level. When the gated signal
is “true”, the generator outputs a continuous waveform. When the gated signal is “false”, the generator rst completes
the output of the current period and then stops. Waveforms that support gated burst include sine, square, ramp, pulse,