User Manual
154 
Waveform 
Parameters 
Sine 
Frequency, Amplitude, Offset 
Square 
Frequency, Amplitude, Offset, Duty (duty cycle) 
Ramp 
Frequency, Amplitude, Offset, Symmetry 
Pulse 
Frequency, Amplitude, Offset, Width 
DC 
Offset 
Noise 
Stdev (standard deviation), Mean 
Cardiac 
Frequency, Amplitude, Offset 
Gaus Pulse 
Frequency, Amplitude, Offset 
Exp Rise 
Frequency, Amplitude, Offset 
Exp Fall 
Frequency, Amplitude, Offset 
Arb 
Frequency, Amplitude, Offset 
Table 11 - Waveform parameters 
The Amplitude and Offset softkeys have two other selections: High-Level and High-Level Fine for 
the amplitude softkey and Low-Level and Low-Level Fine for the offset softkey.  When any of 
these are chosen, the labels on the softkeys change to High-Level and Low-Level.  When the 
softkeys are pressed and the Universal Knob is turned, the peak (High) value and minimum (Low) 
value of the waveform are adjusted. 
The generator's electrical characteristics are: 
Amplitude (all waveforms): 4 mV to 6 V peak-to-peak 
DC offset (all waveforms): ±3.0 V 
Minimum frequency (all waveforms): 1 µHz 
The maximum frequency depends on the waveform: 
Waveform 
Maximum 
frequency, MHz 
Sine 
25 
Square 
10 
Ramp 
0.3 
Pulse 
10 
Cardiac 
5 
Gaus Pulse 
5 
Exp Rise 
5 