User Manual
113 
MATLAB
®
The oscilloscope saves the waveform data to external memory in *.DAT format, an ASCII plain-
text format. You can further analyze the data using MATLAB® or other software. Recalling the 
DAT file is not supported. MATLAB® is a registered trademark of The MathWorks, Inc. 
10.2  Setup Internal Save and Recall 
Save setup to internal memory 
1.  Press the Save/Recall button to enter the SAVE/RECALL menu. 
2.  Press the Save softkey to enter the SAVE menu. 
3.  Press the Type softkey and turn the Universal Knob to select Setups. Press the knob to 
confirm. 
4.  Press the Save To softkey to select Internal to save the current setup of the oscilloscope 
to internal memory. 
5.  Press  the  Setup  softkey  button  and  turn  the  Universal  Knob  to  select  the  memory 
location to save to. There are 20 internal locations that can be saved to. 
6.  Press the Save softkey to save the current setup to the selected location. After a few 
seconds, a message will be displayed saying the operation was successful. 
Load setup from internal memory 
1.  Press the Save/Recall button to enter the SAVE/RECALL menu. 
2.  Press the Recall softkey to enter the RECALL menu. 
3.  Press the Type softkey and turn the Universal Knob to select Setups. Press the knob to 
confirm. 
4.  Press the Recall From softkey and turn the Universal Knob to select Internal. Press the 
knob to confirm. 
5.  Press the Setup softkey and turn the Universal Knob to select the location that you want 
to recall. 
6.  Press the Press To Recall softkey to recall the setup. After a few seconds, a message will 
be displayed saying the operation was successful. 
10.3  External save and recall 
Before using external storage save and recall, make sure a USB storage device is connected. All 
file types are available for external save. Only setups and references are available for external 
recall. 
External Save 
1.  Press the Save/Recall button to enter the SAVE/RECALL menu. 
Note: To delete a setup file in memory, save a new setup to the same location to overwrite it.  