Owner manual
Programmer / Refind programmer
This menu command is used to refind (reestablish communication with) currently selected
programmer.
To select other type of programmer, programmer communication parameters and to establish
communication with newly selected programmer use menu Programmer / Find
programmer.
Programmer / Handler
In dialog Handler a Handler type and Handler communication parameters can be set.
Handler is an external device for special control of device operations in control program.
When None Handler is selected, this means default state of control program, i.e. device
operations are controlled directly by user otherwise control program is in special mode, when
device operations are controlled automatically with co-operation with Handler.
Dialog Handler contains following items:
Selected Handler select wished Handler type.
Search at port select a COM port, which will be scanned for a requested Handler.
Pressing key <Enter> or button OK initiates scanning for Handler by set parameters. If
selected Handler type is None, no Handler scanning will be processed. Current Handler
settings are saved to configuration file by command Options / Save options or when control
program is closed.
Handler is not available for sale.
Programmer / Module options
This option is used for multiple socket programmers for defining MASTER socket and activity
of each socket. MASTER socket group box allows user to set socket which is preferentially
used for device reading operation. Enable/Disable socket checkbox array allows user to set
enabling and disabling of each socket individually. Disabled sockets are ignored for any
device operation.
Programmer / Automatic YES!
This command is used for setting Automatic YES! mode. In this mode you just take off the
programmed device, then put new device into ZIF socket and a last operation will be
repeated automatically. Program automatically detects an insertion of a new device and runs
last executed operation without pressing any key or button. An insertion of device into ZIF is
displayed on the screen. Repeated operation executing will be cancelled by pressing key
<ESC> during waiting for insert/remove a device to/from ZIF.
After an operation with a device is executed, one of the OK or ERROR (status) LEDs on the
programmer will lights in dependence on the result of an operation and the BUSY LED will
blinking.
If the program detects removal of a device, then status LED will switched off, but the BUSY
LED will still blinking to indicate readiness of the program to repeat last operation with new
device.
After the program indicates one or more pins of (new) device in the ZIF socket of the
programmer, the BUSY LED will goes to light continually. From this the program will wait a
97