Owner manual

Connecting 866C to the PC
Using USB port
In this case, order of connecting USB cable and power supply to programmer is irrelevant.
Problems related to the 866C
PC interconnection, and their
removing
If you have any problems with 866C PC interconnection, see section Common notes
please.
Manipulation with the programmed device
After selection of desired device for your work, you can insert into the open ZIF socket (the
lever is up) and close socket (the lever is down). The correct orientation of the programmed
device in ZIF socket is shown on the picture near ZIF socket on the programmer's cover. The
programmed device is necessary to insert into the socket also to remove from the socket
when LED BUSY light off.
Note: Programmer's protection electronics protect the target device and the programmer
itself against either short or long-term power failures and, partly, also against a PC failure.
However, it is not possible to grant the integrity of the target device due to incorrect, user-
selected programming parameters. Target device may be not destroyed by forced interruption
of the control program (reset or switch-off PC), by removing the physical connection to the
programmer, but the content of actually programmed cell may remains undefined. Don't
unplug the target device from the ZIF socket during work with device (LED BUSY shine).
In-system serial programming by 866C
For general definition, recommendation and direction about ISP see section Common notes
/ ISP please.
Description of ISP connector
As ISP connector is used 20 pins connector 2-1634689-0 from TE connectivity or other
compatible connector.
18