User`s manual

844A ISP cable
Warnings:
When you use 844A as ISP programmer, don’t insert
device to ZIF socket.
When you program devices in ZIF socket, don’t insert
ISP cable to ISP connector.
Use only attached ISP cable. When you use other ISP
cable (other material, length…), programming may occur
unreliable.
844A can supply target device only, but target system
cannot supply 844A.
844A apply programming voltage to target device and
checks his value (target system can modify programming
voltage). If the programming voltage is different as
expected, no action with target device will be executed.
Note: H/L/read 844A driver
C1
R1
H/L/read driver
in programmer
pin of ISP
connector
PU/PD driver
in programmer
R2
Self test and calibration
If you feel that your programmer does not react according to
your expectation, please run the programmer selftest using
Diagnostic POD, enclosed with the standard delivery package.
For optimal results with programmer we recommend you
undertake every 6 months, an extended test and to check the
calibration. See instructions for selftest in the Diagnostics
menu of PG4UW.
69