User`s manual
• Use only attached ISP cable. When you use other ISP 
cable (other material, length…), programming may occur 
unreliable. 
• 865  can  supply programmed device (pin 1 of ISP 
connector) and target system (pin 5, 13, 14 of ISP 
connector) with limitation (see Technical specification / ISP 
connector), but target system cannot supply 865. 
• 865 apply programming voltage to target device and 
checks his value (target system can modify programming 
voltage). If the programming voltage is different as 
expected, no action with target device will be executed. 
Note: H/L/read driver on pins 3 and 10 
1n0
315R
H/L/read
driver
ISP
connector
H/L/read driver on pins 2, 4, 6 and 8 
150R
H/L/read
driver
ISP
connector
Self test and Calibration 
If you feel that your programmer does not react according to 
your expectation, please run the programmer self test using 
Diagnostic POD, enclosed with the standard delivery package. 
For optimal results with programmer we recommend you 
undertake every 6 months, an extended test and to check the 
calibration. See instructions for self test in the Diagnostics 
menu of PG4UW. 
Technical specification 
23