User`s manual

and user message about complete count down will be
displayed.
Statistics dialog contains following options:
Check boxes Program, Verify, Blank, Erase and Read define
operations, after which statistics values increment.
Check box Count down sets Count down activity (enable or
disable). Edit box following the Count down check box defines
initial number of count down counter, from which count down
starts.
Statistics dialog can be also opened by pressing right mouse
button on Statistics panel and clicking displayed item Statistics.
Actual statistics values are displaying in main window of
control program in Statistics panel.
Statistics panel contains three statistics values – Success,
Failure, Total and two Count down information values Count
down and Remains.
Meaning of the values is:
Success number of operations which where successfully
completed
Failure number of operations which where not
successfully completed
Total number of all operations
Count down informs about Count down activity (Enabled or
Disabled)
Remains informs about remaining number of device
operations to do
Successful operation means any device operation of these,
which is completed without errors:
program
verify
blank check
erase
read
If device operation is finished with error(s) it is not successful
operation.
When new device type is selected, all statistics values are set
to zero and Count down is set to Disabled.
Reset button in Statistics panel reset statistics values.
Reload Count down button in Statistics panel reloads initial
value to Count down.
129