FRONT PANEL (Refer to Fig. 1) 
1.  POWER Switch. Turns power on and off. 
2.  RANGE Switch. Selects output frequency range. Seven ranges from 1 Hz to 10MHz. Switch indicates maximum frequency of  range 
and is adjusted with COARSE FREQUENCY control to 0.1 times the maximum. For example, if the 100 kHz range is selected, the 
output frequency can be adjusted from 10kHz to 100kHz. 
3.  FUNCTION Switch. Selects sine, square, or triangle waveform at OUTPUT jack. 
4.  OUTPUT LEVEL Control. Controls the amplitude of the signal at the OUTPUT jack. Output level can be decreased by approximately 
20 dB with this control. 
5.  DC OFFSET Control. Enabled by the DC OFFSET Switch (14). Clockwise rotation from center changes the DC offset in a positive 
direction while counterclockwise rotation from center changes the DC offset in a negative direction. 
6.  OUTPUT Jack. Waveform selected by FUNCTION switch as well as the superimposed DC OFFSET voltage is available at this jack. 
7.  TTL/CMOS Jack. TTL or CMOS square wave, depending on the position of the CMOS LEVEL switch (15) is output at this jack. 
This output is independent of the OUTPUT LEVEL and DC OFFSET controls. 
8.  CMOS LEVEL Control. Rotating this control clockwise increases the amplitude of the CMOS square wave at the TTL/CMOS jack. 
9.  VCG/SWEEP Jack. Controlled by SWEEP EXT/INT Switch (12). When SWEEP EXT is selected, jack is the Voltage Controlled 
Generator input and permits external control of generator output frequency by a DC voltage input at this jack. A positive vol tage will 
decrease frequency. 
10.  DUTY CYCLE Control. Enabled by the DUTY CYCLE Switch (17). Rotation from center position adjusts the duty cycle of the main 
OUTPUT signal. 
11.  -20 dB Switch. When engaged, the signal at the OUTPUT jack is attenuated by 20dB. 
12.  SWEEP INT/EXT Switch. When engaged (INT) enables the sweep mode of operation. Sweep rate is controlled by SWEEP TIME control 
(18) and sweep magnitude is controlled by the SWEEP WIDTH control (16). When released (EXT), allows external control of generator 
output frequency by a DC voltage input at the VCG/SWEEP jack (9). 
13.  SWEEP LIN/LOG Switch. When engaged (LOG) selects logarithmic sweep characteristic and in the released (LIN) position selects a 
linear sweep characteristic. 
14.  DC OFFSET Switch. When engaged, enables operation of the DC OFFSET control (5). 
15.  CMOS LEVEL Switch. When engaged, changes the TTL signal to CMOS signal at the TTL/CMOS jack. 
16.  SWEEP WIDTH Control. Rotation determines sweep width by adjusting sweep stop frequency. 