Figure 34 - Slope Trigger Menu
Table 21 - Slope Trigger Function Menu 2
Option
Setting
Description
Type
Slope
Trigger on positive slope or
negative slope according to
setup time of the oscilloscope.
Vertical
Select the trigger level that can
be adjusted by LEVELknob.
You can adjust LEVEL A,
LEVEL Bor adjust them at
the same time.
Mode
Auto
Use this mode to let the acquisition