User Manual
Quick Start Guide 
200 
6.7  Making Cursor Measurements 
You can use the cursors to quickly make time and voltage 
measurements on a waveform. You can use the cursors to 
measure the amplitude and frequency of a FFT waveform. 
You can also use the cursors to measure the phase 
difference between two signals with the  same frequency 
when X-Y horizontal mode is selected. 
Measure the time and voltage on normal waveform 
Perform  the following steps to take time  and frequency 
measurements. 
  Press the CURSOR key to display the CURSOR menu. 
  Press Mode softkey to select the Manual mode. 
  Press Type softkey to select the Time type. 
  Press  X1--/ X2—softkey or press the entry knob to 
select X1 cursor. 
  Rotate the entry knob   to move the X1 cursor. 
  Press  X1--/ X2—softkey or press the entry knob to 
select X2 cursor. 
  Rotate the entry knob   to move the X2 cursor.   
  ΔX and 1/ΔX are displayed in the softkey area.    ΔX is 
the time difference between X1 and X2;  1/ΔX  is the 
frequency between X1 and X2. 