Owner manual

www.bkprecision.com
Handheld Digital Storage Oscilloscopes
2510 Series
7
Multimeter and Recorder Specifications
All specifications are based on operating at temperatures 23 ± 5°C and relative humidity < 75%.
Accuracy is based on ± (% of reading + offset).
Multimeter
Display Resolution
6000 counts
Measurement Function
DC voltage, AC voltage, resistance,
diode, continuity, capacitance,
DC current, AC current
Max. Input Voltage
AC: 750 V (20 Hz - 1 kHz)
DC: 1000 V
Max. Input Current
(1)
AC: 10 A (20 Hz - 1 kHz)
DC: 10 A
Input Impedance
10 M
Max. Input Voltage
Between Multimeter
Input Reference
and Ground
CAT II 600 V
CAT III 300 V
DC Voltage
Range Resolution Accuracy
60.00 mV 10 µV ± (1 % + 15 digits)
600.0 mV 100 µV
± (1 % + 5 digits)
6.000 V 1 mV
60.00 V 10 mV
600.0 V 100 mV
1000 V 1 V
AC Voltage
(2)
Range Resolution Accuracy
60.00 mV 10 µV ± (1 % + 15 digits)
600.0 mV 100 µV
± (1 % + 5 digits)
6.000 V 1 mV
60.00 V 10 mV
600.0 V 100 mV
750 V 1 V
Multimeter (cont.)
Resistance
Range Resolution Accuracy
600.0 0.1
± (1 % + 5 digits)
6.000 k 1
60.00 k 10
600.0 k 100
6.000 M 1 k
60.00 M 10 k
Diode and Continuity Measure
Diode 0 – 2 V
Continuity < 50 alarm
Capacitance
Range Resolution Accuracy
40.00 nF 10 pF ± (3 % + 10 digits)
400.0 nF 100 pF
± (4 % + 5 digits)
4.000 µF 1 nF
40.00 µF 10 nF
400.0 µF 100 nF
DC and AC Current
(3)(4)
Range Resolution Accuracy
60.00 mA 10 µA
± (1 % + 5 digits)
600.0 mA 100 µA
6.000 A 1 mA
± (1.5 % + 5 digits)
10.00 A 10 mA
Recorder
Scope Trend Plot
Display Mode Full view, Normal
Record Length 800k points, > 24 hours
Number of Channels 2
Multimeter Trend Plot
Display Mode Full view, Normal
Record Length 1.2M dots, > 24 hours
Number of Channels 1
Scope Recorder
Display Mode Full view, Normal
Max. Record Length
Single Channel: 7 M pts
Dual Channel: 3.5 M pts
Number of Channels 2
Maximum Record Size to
External Storage
4 GB, 3000 hours
(1) Current input terminals protected with internal 250 V rated fuse.
(2) For frequency range 20 Hz to 1 kHz.
(3) For 10 A terminal, > 6 A DC or AC rms for 10 seconds ON and 15 minutes OFF.
(4) For AC current ranges, frequency is verified for 20 Hz to 1 kHz.
v040714
Included Accessories
User manual, passive probes (one per channel), pair of DMM test leads, 7.4 V Li-ion
battery BP2510, USB cable, probe compensation connector, AC power adapter,
travel hard case LC2510 (models 2515 and 2516 only), and certificate of calibration