User guide
Table Of Contents
- 1 Safety Summary
- 2 Introduction
- 3 Quick Reference
- 4 Operating Instructions
- 4.1 Instrument Hook-Up
- 4.2 Typical Constant Voltage Operation
- 4.3 Setting Current Limit
- 4.4 Typical Constant Current Operation
- 4.5 Constant Voltage/Constant Current Characteristic
- 4.6 Saving the Power Supply’s Current State
- 4.7 Connecting Two Power Supplies in Series
- 4.8 Connecting Two Power Supplies in Parallel
- 5 RS232 Interface
- 6 Maintenance
- 7 Error Messages
- 8 Specifications
- 9 Service Information
- 10 Limited Three-Year Warranty
20
CURR 3000.0<CR>
3. VOLT?<CR>
This command returns the voltage measured to the output terminals of the
power supply: xx.xxV<CR>
The voltage value returned is the same as the one displayed on the voltage
display.
4. CURR?<CR>
This command returns the current measured to the output terminals of the
power supply: xxx.xmA<CR>
The current value returned is the same as the one displayed on the current
display.
5. STAT?<CR>
The power supply responds to this command with one of the following
messages:
CV<CR> if the power supply is in Constant Voltage mode
CC<CR> if the power supply is in Constant Current mode
6. OUT ON<CR>
Turn output power on.
7. OUT OFF<CR>
Turn output power off.
8. IDN?<CR>
The power supply responds with: “B+K PRECISION 1739 Revision x.x <CR>”.