User Manual
28 
Command code & 
Return value 
Function  Example 
Input command: 
GETD[CR] 
Return value: 
[voltage][current][stat
us][CR] 
OK[CR] 
Get display voltage, 
current, and status 
reading from power 
supply 
[voltage] = 0000-XXXX 
[current] = 0000-XXXX 
[status] = 0|1 (0=CV, 
1=CC) 
Input command: 
GETD[CR] 
Return value: 
030201450 
OK 
Indicates voltage reading is 3.02 
V and current reading is 1.45 A. 
Power supply is in CV mode 
Input command: 
GETM[CR] 
Return value: 
[preset 1 voltage] 
[preset 1 current][CR] 
[preset 2 
voltage][preset 2 
current][CR] 
[preset 3 
voltage][preset 3 
current][CR] 
OK[CR] 
Get preset memory 
values 
<preset 1|2|3 
voltage> = 000-XXX 
<preset 1|2|3 
current> = 000-XXX 
Input command: 
GETM[CR] 
Return value: 
015015 
025025 
035035 
OK 
Indicates preset 1 voltage and 
current is 1.5 V and 1.5 A, preset 
2 voltage and current is 2.5 V 
and 2.5 A, preset 3 voltage and 
current is 3.5 V and 3.5 A 
Input command: 
RUNM{<memory>}[CR
] 
Return value: 
OK[CR] 
Set voltage and 
current using values 
saved in preset 
memory locations 
<memory>=0|1|2 
0 = preset 1 values 
1 = preset 2 values 
2 = preset 3 values 
Input command: 
RUNM0[CR] 
Return value: 
OK[CR] 
Sets voltage and current using 
values from memory location 1 