23
STAT:PRES
This command sets the registers of the status groups to their power-on values.
These values are:
Enable Registers: all bits set to 0 (OFF)
Command Syntax: STAT:PRES
Parameters: None
Examples: STAT:PRES
STAT:OPER[:EVEN]?
This query returns the value of the Operation Event register. The Event register is a read-only register
which holds (latches) all events that are passed by the Operation NTR and/or PTR filter. Reading the
Operation Event register clears it.
Query Syntax: STAT:OPER[:EVEN]?
Parameters: None
Examples: STAT:OPER:EVEN?
Returned Parameters: <NR1> (register value)
Related Commands: *CLS
STAT:OPER:COND?
This query returns the value of the Operation Condition register. That is a read-only register which holds
the real-time (unlatched) operational status of the ac source.
Query Syntax: STAT:OPER:COND?
Parameters: None
Examples: STAT:OPER:COND?
Returned Parameters: <NR1> (register value)
Related Commands: STAT:QUES:COND?
STAT:OPER:ENAB
This command and its query set and read the value of the Operation Enable register. This register is a
mask for enabling specific bits from the Operation Event register to set the operation summary bit (OPER)
of the Status Byte register. The operation summary bit is the logical OR of all enabled Operation Event
register bits.
Command Syntax: STAT:OPER:ENAB<sp><NRf+>
Parameters: 0 to 32767 | MAX | MIN
Default Value: 0
Examples: STAT:OPER:ENAB<sp>32 ; STAT:OPER:ENAB<sp>1
Query Syntax: STAT:OPER:ENAB?
Returned Parameters: <NR1> (register value)
Related Commands: STAT:OPER?
STAT:QUES[:EVEN]?
This query returns the value of the Questionable Event register. The Event register is a read-only register
which holds (latches) all events that are passed by the Questionable NTR and/or PTR filter. Reading the
Questionable Event register clears it.
Query Syntax: STATus:QUEStionable[:EVEN]?
Parameters: None
Examples: STAT:QUES:EVEN?
Returned Parameters: <NR1> (register value)
Related Commands: *CLS