User manual
The world of flow
Seite 21
Active edge Low/High
Reset Input R (Pulse Counter)
Pulse shape any
Signal level L<= 0 VDC H>= 5 VDC or open
Max. voltage amplitude ± 30 VDC
Input resistance approx. 1 MOhm
Static response ”Low” - active
min. pulse time 65 ms
Programming Input PROG
Static response “Low” active
Input open Operating mode
Input connected to “0 V” Programming mode
7. Spare Parts
Lithium battery Art.-Nr.: 82202233
Technische Änderungen vorbehalten Stand 7.2011 We reserve the right to make technical changes without notice.
B.I.O-TECH e.K. | Zeitlarner Str. 32 | D- 94474 Vilshofen | Germany
Tel: +49 (0) 8541-91 00 47 | Fax: +49 (0) 8541-96 89 98 0
E-Mail: info@btflowmeter.com | Internet: www.btflowmeter.com