User manual

The world of flow
Seite 19
IEC 68-2-6 Vibration Strength
Variable frequency range 10 to 500 Hz
0.35 mm or 5 g amplitude 10 Frequency
cycles per axis
Dimensions
Frontal dimensions 36 mm x 72 mm
Total depth 38.5 mm
Fastening
Front panel mount via frame
Front panel thickness 0.8 mm to 6 mm
Front panel cutout DIN 43700
33 +0.6 mm x 68 + 0.6 mm
Weight
approx. 95 g
Housing Material / Combustibility
PC plastic
Combustibiity V0 under UL Standard 94
Inputs
Counter Input A (Rate meter)
Pulse shape any
HIGH - SPEED input High active
Signal level L<= 1 VDC H>= 5 VDC
The world of flow
Seite 20
Max. voltage amplitude ± 30 VDC
Input resistance approx. 39 kOhm
Max. frequency (pulse duty factor 1:1) 10 kHz
min. pulse time 50 µs
min. pulse pause 50 µs
Active edge High/Low
Counter Input B (Pulse Counter)
Pulse shape any
Programmed asHIGH - SPEEDinput High” - active
Signal level L<= 1 VDC H>= 5 VDC
Max. voltage amplitude ± 30 VDC
Input resistance approx. 39 kOhm
Max. frequency (pulse duty factor 1:1) 10 kHz
min. pulse time 50 µs
min. pulse pause 50 µs
Active edge High/Low
Programmed asSLOW SPEED input Low” - active
Signal level L<= 0 VDC H>= 5 VDC or open
Max. voltage amplitude ± 30 VDC
Input resistance approx. 1 MOhm
Max. frequency (pulse duty factor 1:1) 30 Hz
min. pulse time 16 ms
min. pulse pause 16 ms