User guide

| 27
Software setup | Zeus Installation Manual
3. Select the ‘Calibrate’ option.
4. Set the ‘actual amount used’ based on amount of fuel added to tank.
5. Select OK to save settings. The ‘Fuel K-Value’ should now show a new value.
Note: To calibrate multiple engines repeat the steps above, one engine at a time. Alterna-
tively, run all engine simultaneously, and divide the ‘Actual amount used’ by the number of
engines. This assumes reasonably even fuel consumption on all engines.
Note: Calibrate option is only available when ‘Set to full’ is selected, and a Fuel Flow is con-
nected and set up as a source.
Note: A maximum of 8 engines is supported using Fuel Flow sensors.
Fuel Level
With the use of a Navico Fluid Level device connected to a suitable tank level sensor, it is
possible to measure the amount of fuel remaining in any equiped tank. The number of tanks
must be set in Vessel Con guration to allow discrete tank assignment of the Fluid Level
devices. Under ‘Device list on the Network page, view the ‘Device Con guration page for each
sensor, and set Tank location, Fluid type, and Tank size.
Refer to the Operator manual on setting up the Instrument bar or a gauge on the Instruments
page using the Fluid Level device data.
Note: A maximum of 5 tanks is supported using Fluid Level devices.
Note: Tank data that is output by a compatible engine gateway can also be displayed, how-
ever tank con guration for such a data source is not possible via the Zeus displays.