User guide
8 |
Wiring | Zeus Installation Manual
Power Control connection
The yellow Power Control wire on the Zeus power cable can either be an input that will turn
on the processor when power is applied, or an output that turns on other devices when the
processor is powered on. It can be con gured at the installation stage to control the power
state of displays and compatible devices. When commissioning the system, the Zeus can be
set to be a Power Control Slave or Power Control Master.
Power Control con guration options of the Zeus are:-
• Zeus to turn on when power key pressed: Yellow wire not connected
• Zeus to turn on when power source is turned on: Common red and yellow wires
• Zeus to turn on with power key, as well as other compatible devices such as Broadband
Radar: Yellow wire connected to a Power Control Bus. (Set one or more displays to be a Power
Control Master)
Power Control unconnected
Device will turn on and o when the power
button on the front of the unit is pressed.
Leave yellow Power Control wire disconnected.
Tape or heat-shrink end to prevent shorting.
Power Control to supply positive (auto on)
Device will turn on immediately when power is
applied. Common the yellow wire with the red
wire after the fuse.
Note: The unit can not be powered down by
power button, but can be put in to standby
mode. (screen backlight also turns o ).
+
_
+