Manual
USING THE ALARM KEY
6
Press the
ALARM
key to cycle through the following
options:
SHA A M
Shallow Alarm, when enabled it will sound if
the water depth is less than the alarm value.
DEP A M
Deep Alarm, when enabled it will sound if
the water depth is more than the alarm
value.
ANC A M
Anchor Alarm, when enabled it will sound if
the water depth is outside two alarm limits.
The display will show
OFF
if the alarm is disabled or the
alarm value when enabled. The value will be displayed in
metres
M
, feet
FT
or fathoms
FA
depending on the
selected depth units.
When the alarm condition is met the unit will sound its
internal alarm buzzer and flash
DEPTH
M
. Silence the
alarm by pressing any key.
Shallow Alarm
Factory set to 1.0m, (3.2ft, 0.5 fathoms).
Range 0 - 180m, 0 - 590ft, 0 - 98.4 fathoms.
Deep Alarm
Factory set to 10.0m, (32.8ft, 5.4 fathoms).
Range 0 - 180m, 0 - 590 ft,
0 - 98.4 fathoms.
Anchor Alarm
Factory set
LOW
0.5m
HI
1.0m,
(1.6/3.2ft, 0.2/.5 fathoms).
Range 0 -180m, 0 - 590 ft,
0 - 98.4 fathoms.
DEPTH ALARMS
10-HB-0501-04
11