Specifications

___________________________________________________H3000 Pilot Handbook
HB-3001-02
75
Clutch Voltage Selection
The ACP computer unit can output different clutch/solenoid voltages
depending upon the size of the rudder drive unit fitted. The
clutch/solenoid valve is only required for rams or rotary drive units. This
is achieved by setting dip switches on the computer drive PCB in the lid
of the computer unit.
Set the switches as per the table below. The default setting is 9V, (switch
4 ON) suitable for size 1, 12V rams and size 2, 12V rams.
DIP Switch Clutch Voltage Drive Size/Type
1 24V 24V Rotary
2 18V Size 3, 24V Ram
3 12V 12V Rotary
4 9V Size 1 and 2 12V Rams
ACP DIP Switch Selection
Note: when using drives from another manufacturer, it is important to
refer to the documentation supplied with that drive to determine the
correct clutch voltage selection. Refer to the manufacturer of the drive for
further information.