8. Press Enter to store the new value into the
system.
9. Press Page to return to full display.
2.4.2 Calibration Adjustment - Depth
1. Select DEPTH.
2. When DEPTH is shown in the upper display,
press and hold the Scroll Down Key to select
CALBRATE from the menu.
Note
Scroll Down is used because we are using an Operation
Menu Choice relating to the function on the upper display.
If DEPTH is in the lower display then Scroll Up must be
used.
3. Select Enter and the display shows DATUM
which flashes.
4. Press Enter again, DATUM stops flashing and
the current datum value is displayed.
5. Press Enter and the DATUM value flashes.
6. Use Scroll Up or Scroll Down to select the new
DATUM value.
Note
If DATUM is referenced to the water line, the value is
positive. If DATUM is referenced to the keel, the value is
negative and this is indicated by a minus sign.
7. Press Enter to store the new DATUM value into
the system.
8. Press Page to return to full display.
2.4.3 Calibration Adjustment - Wind Angle
1. Select MEAS W/A.